If you are getting communication in one direction at startup, and its getting cut off I would suspect windows firewall first. Rockwell won't support the use of VM for Logix but it seems more are going this route. Anyone run into a similar situation and work through this? I am thinking this may be due to the IP of the VM not matching the IP of the Windows7 machine and the controller.

rslogix 500 compatibility windows 7

#Rslogix 500 compatibility windows 7 code

The code downloads to the controller just fine but when I go to online mode it will run for about 3-4 seconds then kick me offline with an error saying I have lost communications to the processor. Linx found the controller and everything looks have written some code in RS500 and set Ch1 to the same IP,subnet, gateway as is currently in the controller.

#Rslogix 500 compatibility windows 7 driver

I was able to add the driver in Linx by hard setting the IP address of the windows machine in the ML1400 controller. Thanks to these posts I was able to get FT, RSLinx and RS500 successfully installed in the VM. Using XP mode in a VM which is on a Windows 7 machine.

#Rslogix 500 compatibility windows 7 software

In the event the software does not operate correctly, users may need to revert back to an operating system that was tested and supported. * Until Windows 7 is supported, use at your own risk. See Answer ID 42682 for the official Rockwell Automation Software Product Compatibility Matrix.

#Rslogix 500 compatibility windows 7 install

then install WinHelp from the following link WinHlp32.exe for Windows 7 then install WinHelp from the following link WinHlp32.exe for Windows Vista

#Rslogix 500 compatibility windows 7 drivers

The RSLinx Classic configured drivers list maybe blank if not disabled. It's recommended that User Account Control (UAC) turned off.

rslogix 500 compatibility windows 7

RSLogix software is not supported for 64-bit operating systems (圆4) and has not been tested in that configuration. RSLogix software is supported for 32-bit operating systems (x86). Quote: 67020 - RSLogix 5/500/5000 on Windows 7Įven though RSLogix 5, 5 have not been officially tested on Windows 7, can they still be installed?Īs long as the Rockwell software package has achieved Windows Vista support, then Technical Support expects it to operate correctly on Windows 7* based on what we've tried so far. I still think DOS was ok, This new stuff is a pain in the hard drive, with all these permissions. I'm glad I was able to get it working, because once rslogix supports windows 7 I will be reformatting to get rid of all this virtual pc stuff. At least this way I don't have to buy a copy of XP-PRO, just to throw it away when rslogix supports windows 7. I am locked out of folders., I don't even know what folders do what. Virtual PC did work, but its huge, and it makes a mess of my directories. Wanna know what I think of this virtual pc stuff?

rslogix 500 compatibility windows 7

At any rate I ran the directories wizard, and it started working as it should. No more nag screen anyway, it appears the problem had to do with setting up factory talk directories. (I say that because these virtual folders have me confused.) Still RSlogix says its not been activated properly. Factory Talk can find the activation key, or at least it shows it in the factory talk current activations list. Then I did some reading some searching, and came across something on rockwell's site saying to use the hard disk, so again I rehosted to the hard disk. Then I fumbled around and tried rehosting, only to find that was a mistake. I tied it to the laptop ethernet adapter the first time. RSLogix 500 programming package is compatible with programs created with Rockwell Software DOS-based programming packages for the SLC 500 and MicroLogix families of processors, making program maintenance across hardware platforms convenient and easy.I was in the XP mode virtual machine when I got it activated. Supporting the Allen-Bradley SLC 500 and MicroLogix families of processors, RSLogix 500 was the first PLC programming software to offer unbeatable productivity with an industry-leading user interface. This family of products has been developed to operate on Microsoft Windows operating systems. The RSLogix family of IEC-1131-compliant ladder logic programming packages helps you maximize performance, save project development time, and improve productivity.